This valve can only be installed when there is a pressurized pump inlet.
Thermal relief valve for cat pump.
Related pumps for thermal valve 7140.
25 frame plunger pump 2510.
During recirculation of by pass liquid the thermal valve will detect temperature rises in the liquid.
2sf direct drive plunger pump 2sf10es.
Fax line 763 780 2958.
Relief valves pop off valves pulsation dampeners.
When the water cools the wax re hardens and pushes the spring loaded pin back into the seat stopping wa.
Related pumps for pressure relief valve 7595.
Main line 763 780 5440.
The product range is up to 25 gpm with 125 psi.
Thermal valves pulse pumps mag jets.
There are no pumps associated with this product.
Designed and built to the highest quality standards customers count on cat pumps products to keep their equipment.
This cat pump relief valve eliminates heat build up in a closed loop by pass system when liquid is being returned to the pump inlet.
3 0 x 88 choice of three port sizes to allow convenient and easy installation into the by pass loop.
25625 cat drain plug 25 frame pumps 5 95 5 95 add to cart.
26516 cat pump shaft protector 25fr 28fr pumps 24 95 24 95 add to cart.
For 50 years cat pumps has offered the most dependable positive displacement high pressure triplex pumps available.
Thermal valves pulse pumps mag jets guns lances nozzles.
Main line 763 780 5440.
Related pumps for thermal valve 7145.
Once the set temperature is reached a bleed port dumps a portion of the overheated fluid.
Main line 763 780 5440.
25 frame piston pump 2520.
Fax line 763 780 2958.
A thermal valve is used to eliminate heat build up in a closed loop by pass system when liquid is being returned to the pump inlet.
Thermal valves can only be installed when there is a pressurized pump inlet.
The key benefit of the thermal relief valve is that it allows an operator to run a unit in a bypass mode for an extended period which reduces the changes of premature seal wear on the high pressure pump.
Relief valves pop off valves pulsation dampeners.
Brass thermo cat valve 145 1 2 protects pump from premature failure of seals and cups by eliminating heat build up in closed loop by pass systems.
Temperature relief valve 165 degrees 1 2 mpt a small ball of wax melts releasing a spring loaded pin and allowing water to bypass through the end.
Relief valves pop off valves pulsation dampeners.
25128 cat inlet manifold brass chrome plated 280 290 pumps 149 95 149 95 add to cart.
20262 cat discharge valve 623 820 1010 pumps 19 50 19 50 add to cart.
Fax line 763 780 2958.