The slab should have a thickened edge at the wall with a couple of 5 s running the lenght of the opening.
Thickened slab at garage door opening.
The wall should be stepped down at the the door 8 10 below the top of the slab.
I am leaning toward option 2 in the sketch i e.
Tie the slab to the foundation wall at the door.
Yes use expansion joints.
Extend the slab through the door opening to align with outside face of wall and thicken the slab edge locally at the door but not thick enough to bear on the wall footing.
That can be bent into the slab.
Some existing garage slabs will not have a thickened footing that runs beneath the slab in the garage door opening.
In these cases it is often required to dig under the slab and add a footing to support the new wall above.
Pouring just a slab with a thickened perimeter is the least expensive and a perfectly acceptable option if you have good soil conditions not spongy.
Option 2 completely blocks out the stemwall at the garage door and then a thicken edge is poured where the slab meets the footing at the garage door this seems to be the preferred method in western washington.
It s like a garage door re.
The wall should have a key and 5 bars at 12 16 o c.
Once we have determined what height the foundation wall needs to be above the lowest top of slab height and take into account the 12 inches of thickened slab the drop in the wall for an overhead garage door is pretty easy to calculate.
The figure to the right shows one way that can be done.
If your in rain country provide a depression in the slab where your door closes about an inch deep 6 wide and about 3 wider than your door opening to keep water out.
Mostly for lightly loaded.
There is a world of difference between the three types and which one will be.
Finishingconcrete concretefinishingtechniques mikedayconcrete in this video i m teaching you about finishing concrete at the garage door openings.
For other options speak to your jurisdiction.
Type 1 is sometimes referred to as a thickened slab garage foundation and type 2 is often referred to as a stem wall garage foundation and type 3 is often referred to as a hybrid stem wall garage foundation for the reason that it is a combination of both type 1 and type 2 and is often used in areas that have highly plastic soils conditions such as is found in south dakota and other parts of the u s a.
We set the vertical depth of the thickened slab at a minimum of 8 inches below the 4 inches of actual floor slab or 12 inches below the lowest top of slab height.